Official Description

Programming device evaluation (in-person) with iterative adjustment of the implantable device to test the function of the device and select optimal permanent programmed values with analysis, review and report by a physician or other qualified health care professional, permanent implantable synchronized diaphragmatic stimulation system for augmentation of cardiac function

© Copyright 2026 American Medical Association. All rights reserved.

Common Language Description

A programming device evaluation is a critical procedure performed on an implantable synchronized diaphragmatic stimulation (SDS) system. This evaluation involves an in-person assessment where iterative adjustments are made to the implantable device. The primary goal is to test the device's function and select optimal permanent programmed values. During this process, a physician or other qualified healthcare professional conducts a thorough analysis and review, culminating in a written report that documents the findings and adjustments made. The patient undergoing this evaluation is typically connected to an electrocardiogram (ECG) monitor to continuously assess cardiac activity. A connection is established between the SDS device and specialized programming software, allowing for a comprehensive review of the device's current programming. Key aspects such as the SDS sensing function, leads, and battery status are evaluated to ensure proper operation. Additionally, the cardiac rhythm is monitored, and parameters such as generator voltage, lead impedance, and pulse width are meticulously reviewed, measured, and adjusted as necessary. This careful calibration of the device is essential for stimulating the diaphragm in sync with the cardiac cycle, which in turn modifies chest pressure to enhance the heart's filling and emptying processes, ultimately improving blood flow. After adjustments are made, the parameters are tested, and any required reprogramming of the device is performed based on the evaluation results. Finally, the patient receives instructions regarding any necessary follow-up services to ensure ongoing care and monitoring of the device's performance.

© Copyright 2026 Coding Ahead. All rights reserved.

CasePilot
Have a question about CPT® Code 0683T?

Get instant expert-level answers from CasePilot, our coding assistant.

Register to view content

Create a free account to unlock this content

Register to view content

Create a free account to unlock this content

Register to view content

Create a free account to unlock this content

Register to view content

Create a free account to unlock this content

Register to view content

Create a free account to unlock this content

CasePilot

Get instant expert-level medical coding assistance.

Ask about:
CPT Codes Guidelines Modifiers Crosswalks NCCI Edits Compliance Medicare Coverage
Example: "What is CPT code 99213?" or "Guidelines for E/M services"