A fetal lung maturity assessment is a critical procedure performed to evaluate the development of the fetus's lungs prior to delivery. This assessment can be conducted using three different methods: foam stability test (CPT® Code 83662), fluorescence polarization (CPT® Code 83663), and lamellar body density (CPT® Code 83664). The primary purpose of these tests is to analyze amniotic fluid, which provides essential information regarding the likelihood of neonatal respiratory distress syndrome (RDS), also known as hyaline membrane disease, occurring after birth. By assessing lung maturity, healthcare providers can make informed decisions about whether to intervene in cases of premature labor or to allow the delivery to proceed based on the maturity of the fetal lungs. Additionally, these assessments are crucial in situations where the health of the mother or fetus is compromised, as they help determine if the lungs are sufficiently mature to safely induce labor. The fluorescence polarization method, specifically associated with CPT® Code 83663, utilizes an automated fluorescence polarimeter to measure the concentration of specific lipids in the amniotic fluid, providing a quantitative assessment of lung maturity.
© Copyright 2026 Coding Ahead. All rights reserved.
The fetal lung maturity assessment using fluorescence polarization (CPT® Code 83663) is indicated in the following scenarios:
The procedure for conducting a fetal lung maturity assessment using fluorescence polarization involves several key steps:
After the fetal lung maturity assessment using fluorescence polarization, the results are typically reviewed by the healthcare provider to make informed clinical decisions. Depending on the findings, the provider may discuss the implications of the results with the patient, including the potential need for interventions related to labor and delivery. It is important to monitor the patient for any signs of complications and to provide appropriate follow-up care based on the assessment outcomes.
| Short Descr | FLUORO POLARIZE FETAL LUNG | Medium Descr | FETAL LUNG MATURITY FLUORESCENCE POLARIZATION | Long Descr | Fetal lung maturity assessment; fluorescence polarization | Status Code | Statutory Exclusion (from MPFS, may be paid under other methodologies) | Global Days | XXX - Global Concept Does Not Apply | PC/TC Indicator (26, TC) | 9 - Not Applicable | Multiple Procedures (51) | 9 - Concept does not apply. | Bilateral Surgery (50) | 9 - Concept does not apply. | Physician Supervisions | 09 - Concept does not apply. | Assistant Surgeon (80, 82) | 9 - Concept does not apply. | Co-Surgeons (62) | 9 - Concept does not apply. | Team Surgery (66) | 9 - Concept does not apply. | Diagnostic Imaging Family | 99 - Concept Does Not Apply | CLIA Waived (QW) | No | APC Status Indicator | Conditionally packaged laboratory tests | Type of Service (TOS) | 5 - Diagnostic Laboratory | Berenson-Eggers TOS (BETOS) | T1H - Lab tests - other (non-Medicare fee schedule) | MUE | 3 | CCS Clinical Classification | 233 - Laboratory - Chemistry and Hematology |
|
Date
|
Action
|
Notes
|
|---|---|---|
| 2011-01-01 | Changed | Short description changed. |
| 2001-01-01 | Added | First appearance in code book in 2001. |