Coding Ahead
CasePilot
Medical Coding Assistant
CaseConsultant
Instant Email Coding Consultant
Case2Code
Search and Code Lookup Tool
CareerCenter
Medical Coding Job Board
Log in Register free account
0 code page views remaining. Guest accounts are limited to 1 page view. Register free account to get 5 more views.
Log in Register free account

Official Description

Electrophysiologic evaluation of subcutaneous implantable defibrillator (includes defibrillation threshold evaluation, induction of arrhythmia, evaluation of sensing for arrhythmia termination, and programming or reprogramming of sensing or therapeutic parameters)

© Copyright 2026 American Medical Association. All rights reserved.

Common Language Description

The CPT® Code 93644 pertains to the electrophysiologic evaluation of a subcutaneous implantable defibrillator. This procedure is essential for assessing the functionality and effectiveness of the implanted device, which is designed to monitor and treat life-threatening arrhythmias. The evaluation includes several critical components: the defibrillation threshold evaluation, which determines the minimum energy required to successfully defibrillate the heart; the induction of arrhythmia, where a controlled arrhythmia is provoked to test the device's response; the evaluation of sensing capabilities for arrhythmia termination, ensuring the device can accurately detect and respond to abnormal heart rhythms; and the programming or reprogramming of sensing or therapeutic parameters to optimize the device's performance based on the patient's current medical status. Regular evaluations, typically conducted every 1-6 months by a cardiologist or electrophysiologist, are crucial for ensuring the device operates effectively, especially if the patient's condition changes or if the device fails to deliver appropriate treatment. The procedure also involves retrieving stored data from the defibrillator, which can provide insights into the frequency and nature of arrhythmias experienced by the patient, as well as any inappropriate shocks that may have been delivered due to misinterpretation of the heart's rhythm. This comprehensive evaluation process is vital for maintaining the safety and efficacy of the subcutaneous implantable defibrillator in managing the patient's cardiac health.

© Copyright 2026 Coding Ahead. All rights reserved.

CasePilot
Have a question about CPT® Code 93644?

Get instant expert-level answers from CasePilot, our coding assistant.

Register to view content

Create a free account to unlock this content

Register to view content

Create a free account to unlock this content

Register to view content

Create a free account to unlock this content

Register to view content

Create a free account to unlock this content

Register to view content

Create a free account to unlock this content

Register to view content

Create a free account to unlock this content

CasePilot

Get instant expert-level medical coding assistance.

Ask about:
CPT Codes Guidelines Modifiers Crosswalks NCCI Edits Compliance Medicare Coverage
Example: "What is CPT code 99213?" or "Guidelines for E/M services"