Coding Ahead
CasePilot
Medical Coding Assistant
Case2Code
Search and Code Lookup Tool
CareerCenter
Medical Coding Job Board
Log in Register free account

Need help choosing the right code?

Ask CasePilot about procedures, modifiers, bundling, and coding guidance.

Try CasePilot
Code deleted, see 33274, 33275, 93279, 93286, 93288, 93294, 93296

Official Description

Peri-procedural device evaluation (in person) and programming of device system parameters before or after a surgery, procedure or test with analysis, review and report, leadless pacemaker system

© Copyright 2026 American Medical Association. All rights reserved.

Common Language Description

The CPT® Code 0390T refers to the peri-procedural evaluation and programming of a leadless pacemaker system. This procedure is essential for patients who have a leadless pacemaker and may need adjustments to their device settings before or after undergoing surgical interventions, medical tests, or other procedures. During this evaluation, electrocardiogram (ECG) electrodes are strategically placed on the patient's chest and extremities to monitor the heart's electrical activity. These electrodes are then connected to a specialized computer equipped with software designed to download and display data from the pacemaker. The clinician conducts a thorough review and analysis of the downloaded information, which allows for the necessary adjustments to be made to the device's programmed parameters. Following this evaluation, a comprehensive written report detailing the findings and any modifications made to the leadless pacemaker system is provided. This process ensures that the device functions optimally, enhancing patient safety and the effectiveness of subsequent medical interventions.

© Copyright 2026 Coding Ahead. All rights reserved.

1. Indications

The peri-procedural device evaluation and programming of a leadless pacemaker system is indicated for patients who have undergone or are scheduled to undergo surgical procedures, medical tests, or other interventions that may impact the functioning of their pacemaker. The following conditions warrant this evaluation:

  • Adjustment Needs Patients may require adjustments to their leadless pacemaker settings to ensure optimal performance during and after medical procedures.
  • Monitoring Heart Activity Continuous monitoring of the heart's electrical activity is necessary to assess the pacemaker's functionality and make any required modifications.
  • Pre-Procedure Preparation Prior to surgery or medical tests, evaluating the device ensures that it is appropriately programmed to support the patient's cardiac needs.
  • Post-Procedure Assessment After a procedure, it is crucial to evaluate the pacemaker to confirm that it is operating correctly and to adjust settings as needed based on the patient's condition.

2. Procedure

The procedure for peri-procedural device evaluation and programming of a leadless pacemaker system involves several critical steps to ensure accurate assessment and adjustment of the device.

  • Step 1: Patient Preparation The patient is prepared for the procedure by ensuring that they are in a comfortable position, and the area where the electrodes will be placed is cleaned and prepared to minimize any risk of infection.
  • Step 2: Electrode Placement Electrocardiogram electrodes are placed on the patient's chest and extremities. This placement is crucial for accurately capturing the heart's electrical signals and ensuring effective communication with the pacemaker.
  • Step 3: Device Connection The electrodes are connected to a computer that is equipped with specialized software. This software is designed to interface with the leadless pacemaker, allowing for the retrieval of data stored within the device.
  • Step 4: Data Downloading The clinician initiates the data download process, which transfers information from the pacemaker to the computer. This data includes the device's performance metrics and any recorded events that may have occurred since the last evaluation.
  • Step 5: Data Analysis Once the data is downloaded, the clinician reviews and analyzes the information displayed on the screen. This analysis helps identify any necessary adjustments to the device's programmed parameters based on the patient's current cardiac status.
  • Step 6: Programming Adjustments Based on the analysis, the clinician makes any required adjustments to the device settings to optimize its performance. This may involve changing pacing thresholds, sensitivity settings, or other parameters to better suit the patient's needs.
  • Step 7: Documentation After completing the evaluation and adjustments, the clinician prepares a written report that details the findings of the evaluation, the adjustments made, and any recommendations for future monitoring or follow-up.

3. Post-Procedure

Following the peri-procedural device evaluation and programming, the patient may be monitored for a short period to ensure that the leadless pacemaker is functioning correctly with the new settings. The clinician may provide specific instructions regarding any follow-up appointments or additional monitoring that may be necessary. It is important for the patient to report any unusual symptoms or changes in their condition after the procedure, as this may indicate the need for further evaluation or adjustments to the device. The written report generated during the procedure serves as a critical document for ongoing patient care and should be included in the patient's medical records for future reference.

Short Descr PERIPROC EVAL INPER LEDLS PM
Medium Descr PERI-PROC DEVICE EVAL IN PERS LEADLESS PM SYSTEM
Long Descr Peri-procedural device evaluation (in person) and programming of device system parameters before or after a surgery, procedure or test with analysis, review and report, leadless pacemaker system
Status Code Carriers Price the Code
Global Days XXX - Global Concept Does Not Apply
PC/TC Indicator (26, TC) 0 - Physician Service Code
Multiple Procedures (51) 0 - No payment adjustment rules for multiple procedures apply.
Bilateral Surgery (50) 0 - 150% payment adjustment for bilateral procedures does NOT apply.
Physician Supervisions 09 - Concept does not apply.
Assistant Surgeon (80, 82) 0 - Payment restriction for assistants at surgery applies to this procedure...
Co-Surgeons (62) 0 - Co-surgeons not permitted for this procedure.
Team Surgery (66) 0 - Team surgeons not permitted for this procedure.
Diagnostic Imaging Family 99 - Concept Does Not Apply
APC Status Indicator Items and Services Packaged into APC Rates
Berenson-Eggers TOS (BETOS) I4A - Imaging/procedure - heart including cardiac catheter
MUE Not applicable/unspecified.
Date
Action
Notes
2019-01-01 Deleted Code deleted, see 33274, 33275, 93279, 93286, 93288, 93294, 93296
2016-01-01 Added First appearance in codebook.
2015-01-01 Added Added
Code
Description
Code
Description
CasePilot

Get instant expert-level medical coding assistance.

Ask about:
CPT Codes Guidelines Modifiers Crosswalks NCCI Edits Compliance Medicare Coverage
Example: "What is CPT code 99213?" or "Guidelines for E/M services"