© Copyright 2026 American Medical Association. All rights reserved.
The procedure described by CPT® Code 0328T involves a comprehensive programming device evaluation of an implantable subcutaneous lead defibrillator system. This evaluation is conducted in person by a cardiac electrophysiologist during a patient encounter. The primary goal of this procedure is to ensure the optimal functioning of the defibrillator device by making iterative adjustments based on real-time assessments. During the evaluation, the patient is connected to an electrocardiogram (ECG) monitor, which allows for continuous monitoring of the cardiac rhythm. The electrophysiologist establishes a connection between the defibrillator system and a programming device to facilitate the interrogation of the device's stored data. This data includes information on cardiac rhythm and any episodes of tachyarrhythmia, which are critical for understanding the patient's heart function and the device's performance. The procedure also involves assessing the pacing capture threshold, which determines the minimum electrical stimulus required to induce a heartbeat. Additionally, the pacing function is evaluated, including the integrity of the leads and the battery status of the device. Any issues related to device integrity are addressed during this evaluation. The sensing threshold data is also reviewed to ensure that the device can accurately detect the heart's electrical activity. To achieve optimal programmed values, an iterative programming process is employed, allowing for adjustments based on the effects of programming on various parameters, including ventricular pacing, hemodynamics, and the heart's response to different stimuli. The electrophysiologist reviews exercise and physiological stress data to observe heart rate adaptations, which further informs the programming adjustments. After a thorough evaluation of all relevant variables, the programmed parameters are modified as necessary. The patient is then informed of the findings, and a written report is generated, which includes instructions for any required follow-up services or procedures.
© Copyright 2026 Coding Ahead. All rights reserved.
Get instant expert-level answers from CasePilot, our coding assistant.
Create a free account to unlock this content
Create a free account to unlock this content
Create a free account to unlock this content
Create a free account to unlock this content
Create a free account to unlock this content
Get instant expert-level medical coding assistance.