Official Description

Programming device evaluation (in person) with iterative adjustment of the implantable device to test the function of the device and select optimal permanent programmed values with analysis, review and report by a physician or other qualified health care professional; single lead transvenous implantable defibrillator system

© Copyright 2026 American Medical Association. All rights reserved.

Common Language Description

The CPT® Code 93282 refers to the process of programming device evaluation for a single lead transvenous implantable defibrillator system. This procedure is conducted in person and involves a comprehensive assessment of the device's functionality. During the evaluation, iterative adjustments are made to the implantable device to ensure optimal permanent programmed values are selected. The procedure includes a thorough analysis, review, and reporting by a physician or other qualified healthcare professional. The patient is connected to an electrocardiogram (ECG) monitor to facilitate real-time monitoring of cardiac activity. The evaluation process encompasses several critical steps, including the interrogation of current stored data related to cardiac rhythm and tachyarrhythmia episodes, which are then compared with previous data acquisitions. Additionally, the pacing capture threshold is assessed in each chamber, and the overall pacing function, including the integrity of leads and battery, is evaluated. The procedure also involves obtaining sensing threshold data from each chamber and assessing for cross-talk, which occurs when stimulation of one chamber inadvertently activates another. Atrial and ventricular stimulation tests are performed to check for phrenic nerve stimulation. To achieve optimal device settings, an iterative programming process is utilized, adjusting parameters based on their effects on ventricular pacing, hemodynamics, and the heart's response. The evaluation also includes a review of exercise and physiological stress data, noting heart rate adaptations. Any necessary reprogramming of the defibrillator system is conducted after a careful evaluation of all parameters, ensuring the device functions effectively. Finally, the patient receives instructions regarding any required follow-up services or procedures, ensuring continuity of care.

© Copyright 2026 Coding Ahead. All rights reserved.

CasePilot
Have a question about CPT® Code 93282?

Get instant expert-level answers from CasePilot, our coding assistant.

Register to view content

Create a free account to unlock this content

Register to view content

Create a free account to unlock this content

Register to view content

Create a free account to unlock this content

Register to view content

Create a free account to unlock this content

Register to view content

Create a free account to unlock this content

Register to view content

Create a free account to unlock this content

CasePilot

Get instant expert-level medical coding assistance.

Ask about:
CPT Codes Guidelines Modifiers Crosswalks NCCI Edits Compliance Medicare Coverage
Example: "What is CPT code 99213?" or "Guidelines for E/M services"