Coding Ahead
CasePilot
Medical Coding Assistant
CaseConsultant
Instant Email Coding Consultant
Case2Code
Search and Code Lookup Tool
CareerCenter
Medical Coding Job Board
Log in Register free account
0 code page views remaining. Guest accounts are limited to 1 page view. Register free account to get 5 more views.
Log in Register free account

Official Description

Programming device evaluation (in person) with iterative adjustment of the implantable device to test the function of the device and select optimal permanent programmed values with analysis, review and report by a physician or other qualified health care professional; multiple lead transvenous implantable defibrillator system

© Copyright 2026 American Medical Association. All rights reserved.

Common Language Description

The CPT® Code 93284 refers to a comprehensive in-person programming device evaluation specifically for a multiple lead transvenous implantable defibrillator system. This procedure involves a detailed assessment and iterative adjustment of the implantable device to ensure its optimal functionality. During the evaluation, the patient is connected to an electrocardiogram (ECG) monitor, allowing for real-time monitoring of cardiac rhythms. The process includes establishing a connection between the defibrillator system and the programming device, which facilitates the interrogation and review of stored data related to the patient's cardiac rhythm and any tachyarrhythmia episodes. The physician or qualified healthcare professional conducts a thorough analysis, assessing various parameters such as pacing capture thresholds, pacing function, and sensing thresholds across each chamber of the heart. The evaluation also includes testing for cross-talk, which occurs when stimulation in one chamber inadvertently affects another, and assessing for phrenic nerve stimulation during atrial and ventricular stimulation. The iterative programming process is crucial for determining the optimal settings for the device, taking into account the effects on ventricular pacing, hemodynamics, and the heart's overall response. Additionally, the evaluation involves reviewing exercise and physiological stress data to observe heart rate adaptations. Following the assessment, any necessary adjustments to the programmed parameters are made, and reprogramming of the defibrillator system is performed as needed. The patient is then provided with instructions regarding any follow-up services or procedures that may be required.

© Copyright 2026 Coding Ahead. All rights reserved.

CasePilot
Have a question about CPT® Code 93284?

Get instant expert-level answers from CasePilot, our coding assistant.

Register to view content

Create a free account to unlock this content

Register to view content

Create a free account to unlock this content

Register to view content

Create a free account to unlock this content

Register to view content

Create a free account to unlock this content

Register to view content

Create a free account to unlock this content

Register to view content

Create a free account to unlock this content

CasePilot

Get instant expert-level medical coding assistance.

Ask about:
CPT Codes Guidelines Modifiers Crosswalks NCCI Edits Compliance Medicare Coverage
Example: "What is CPT code 99213?" or "Guidelines for E/M services"