Coding Ahead
CasePilot
Medical Coding Assistant
CaseConsultant
Instant Email Coding Consultant
Case2Code
Search and Code Lookup Tool
CareerCenter
Medical Coding Job Board
Log in Register free account
0 code page views remaining. Guest accounts are limited to 1 page view. Register free account to get 5 more views.
Log in Register free account

Official Description

Programming device evaluation (in person) with iterative adjustment of the implantable device to test the function of the device and select optimal permanent programmed values with analysis, review and report by a physician or other qualified health care professional; dual lead transvenous implantable defibrillator system

© Copyright 2026 American Medical Association. All rights reserved.

Common Language Description

The CPT® Code 93283 refers to the in-person programming device evaluation of a dual lead transvenous implantable defibrillator system. This procedure involves a comprehensive assessment where the healthcare professional iteratively adjusts the implantable device to ensure optimal functionality. The evaluation includes testing the device's performance and selecting the best permanent programmed values. During this process, the patient is connected to an electrocardiogram (ECG) monitor, allowing for real-time monitoring of cardiac activity. The healthcare provider establishes a connection between the defibrillator system and the programming device to facilitate the evaluation. Key aspects of the procedure include assessing the cardiac rhythm, reviewing current stored data related to previous tachyarrhythmia episodes, and comparing this data with earlier acquisitions. The evaluation also involves determining the pacing capture threshold in each chamber, assessing the pacing function, and addressing any issues related to leads or battery integrity. Additionally, the procedure evaluates sensing thresholds and cross-talk, which occurs when stimulation in one chamber inadvertently affects another. Atrial and ventricular stimulation tests are performed to check for phrenic nerve stimulation. The iterative programming process is crucial for adjusting parameters such as the atrioventricular interval timing, based on the effects observed on ventricular pacing and overall heart response. The healthcare professional reviews exercise and physiological stress data to note heart rate adaptations and makes necessary adjustments to the programmed parameters. After a thorough evaluation, any required reprogramming of the defibrillator system is conducted, and the patient receives instructions regarding follow-up services or procedures. This code is specifically designated for dual lead systems, while separate codes exist for single lead and multiple lead systems.

© Copyright 2026 Coding Ahead. All rights reserved.

CasePilot
Have a question about CPT® Code 93283?

Get instant expert-level answers from CasePilot, our coding assistant.

Register to view content

Create a free account to unlock this content

Register to view content

Create a free account to unlock this content

Register to view content

Create a free account to unlock this content

Register to view content

Create a free account to unlock this content

Register to view content

Create a free account to unlock this content

Register to view content

Create a free account to unlock this content

CasePilot

Get instant expert-level medical coding assistance.

Ask about:
CPT Codes Guidelines Modifiers Crosswalks NCCI Edits Compliance Medicare Coverage
Example: "What is CPT code 99213?" or "Guidelines for E/M services"