Official Description

Electronic analysis of implanted neurostimulator pulse generator system (eg, rate, pulse amplitude, pulse duration, configuration of wave form, battery status, electrode selectability, output modulation, cycling, impedance and patient compliance measurements); complex spinal cord, or peripheral (ie, peripheral nerve, sacral nerve, neuromuscular) (except cranial nerve) neurostimulator pulse generator/transmitter, with intraoperative or subsequent programming, each additional 30 minutes after first hour (List separately in addition to code for primary procedure)

© Copyright 2026 American Medical Association. All rights reserved.

Common Language Description

The CPT® Code 95973 pertains to the electronic analysis of an implanted neurostimulator pulse generator system. This procedure involves a comprehensive evaluation of various parameters associated with the neurostimulator, including the rate of stimulation, pulse amplitude, pulse duration, and the configuration of the waveform. Additionally, it assesses the battery status, electrode selectability, output modulation, cycling, impedance, and measurements related to patient compliance. This code specifically applies to complex neurostimulator systems that are utilized in spinal cord or peripheral nerve applications, excluding cranial nerve systems. The procedure is categorized as an add-on code, indicating that it is billed separately in conjunction with the primary procedure code. The analysis and programming of the neurostimulator pulse generator can occur intraoperatively or during subsequent follow-up visits, with this code specifically representing each additional 30 minutes of programming after the first hour has been completed. This detailed analysis is crucial for ensuring the optimal functioning of the neurostimulator, which plays a significant role in managing various neurological conditions.

© Copyright 2026 Coding Ahead. All rights reserved.

1. Indications

The CPT® Code 95973 is indicated for use in the electronic analysis and programming of complex implanted neurostimulator pulse generator systems. The specific indications for this procedure include:

  • Complex Neurostimulator Systems These systems are utilized for therapeutic interventions in conditions affecting the spinal cord or peripheral nerves, such as chronic pain management or neuromuscular disorders.
  • Intraoperative Programming This procedure may be performed during the surgical implantation of the neurostimulator to ensure proper functionality and settings before closing the surgical site.
  • Subsequent Programming Follow-up visits may require additional programming to adjust the neurostimulator settings based on patient response and compliance, ensuring optimal therapeutic outcomes.

2. Procedure

The procedure associated with CPT® Code 95973 involves several key steps that ensure the effective programming and analysis of the implanted neurostimulator pulse generator. Each step is critical for achieving the desired therapeutic effects.

  • Initial Assessment The healthcare provider begins by assessing the patient's current condition and the functionality of the implanted neurostimulator. This includes reviewing the patient's medical history and any previous programming adjustments.
  • Electronic Analysis The provider conducts a thorough electronic analysis of the neurostimulator pulse generator. This involves checking various parameters such as the rate of stimulation, pulse amplitude, pulse duration, and waveform configuration to ensure they are set correctly for the patient's needs.
  • Battery and Electrode Evaluation The status of the battery is evaluated to confirm that it is functioning optimally. Additionally, the provider assesses electrode selectability and output modulation to ensure that the neurostimulator is delivering the appropriate stimulation to the targeted areas.
  • Impedance Measurement Impedance measurements are taken to evaluate the integrity of the electrode connections and the overall system performance. This step is crucial for identifying any potential issues that may affect the neurostimulator's efficacy.
  • Patient Compliance Assessment The provider reviews patient compliance measurements to determine how well the patient is adhering to the prescribed therapy. This information is vital for making necessary adjustments to the programming.
  • Programming Adjustments Based on the findings from the analysis, the provider makes any necessary programming adjustments to optimize the neurostimulator's performance. This may involve changing stimulation parameters or settings to better align with the patient's therapeutic goals.

3. Post-Procedure

After the programming and analysis of the neurostimulator pulse generator are completed, the patient may be monitored for a brief period to ensure that the device is functioning as intended. The healthcare provider will typically provide instructions regarding any follow-up appointments necessary for ongoing monitoring and adjustments. Patients may also be advised on how to report any issues or changes in their condition that could affect the neurostimulator's performance. It is essential for patients to adhere to follow-up schedules to ensure optimal management of their therapy and to address any potential complications that may arise.

Short Descr ANALYZE NEUROSTIM COMPLEX
Medium Descr ELEC ALYS NSTIM PLS GEN CPLX SC/PERPH EA 30 MIN
Long Descr Electronic analysis of implanted neurostimulator pulse generator system (eg, rate, pulse amplitude, pulse duration, configuration of wave form, battery status, electrode selectability, output modulation, cycling, impedance and patient compliance measurements); complex spinal cord, or peripheral (ie, peripheral nerve, sacral nerve, neuromuscular) (except cranial nerve) neurostimulator pulse generator/transmitter, with intraoperative or subsequent programming, each additional 30 minutes after first hour (List separately in addition to code for primary procedure)
Status Code Active Code
Global Days ZZZ - Code Related to Another Service
PC/TC Indicator (26, TC) 0 - Physician Service Code
Multiple Procedures (51) 0 - No payment adjustment rules for multiple procedures apply.
Bilateral Surgery (50) 0 - 150% payment adjustment for bilateral procedures does NOT apply.
Physician Supervisions 09 - Concept does not apply.
Assistant Surgeon (80, 82) 0 - Payment restriction for assistants at surgery applies to this procedure...
Co-Surgeons (62) 0 - Co-surgeons not permitted for this procedure.
Team Surgery (66) 0 - Team surgeons not permitted for this procedure.
Diagnostic Imaging Family 99 - Concept Does Not Apply
APC Status Indicator Items and Services Packaged into APC Rates
Type of Service (TOS) 5 - Diagnostic Laboratory
Berenson-Eggers TOS (BETOS) T2D - Other tests - other
MUE Not applicable/unspecified.
CCS Clinical Classification 7 - Other diagnostic nervous system procedures
Date
Action
Notes
2016-01-01 Deleted Deleted
2012-01-01 Changed Description Changed
2011-01-01 Changed Short description changed.
2005-01-01 Changed Code description changed.
1999-01-01 Added First appearance in code book in 1999.
Code
Description
Code
Description
Code
Description
CasePilot

Get instant expert-level medical coding assistance.

Ask about:
CPT Codes Guidelines Modifiers Crosswalks NCCI Edits Compliance Medicare Coverage
Example: "What is CPT code 99213?" or "Guidelines for E/M services"