Coding Ahead
CasePilot
Medical Coding Assistant
Case2Code
Search and Code Lookup Tool
CareerCenter
Medical Coding Job Board
Log in Register free account

Need help choosing the right code?

Ask CasePilot about procedures, modifiers, bundling, and coding guidance.

Try CasePilot

Official Description

Interrogation device evaluation (in person) with analysis, review and report, includes connection, recording and disconnection per patient encounter, implantable aortic counterpulsation ventricular assist system, per day

© Copyright 2026 American Medical Association. All rights reserved.

Common Language Description

The CPT® Code 0463T refers to the in-person interrogation device evaluation of an implantable aortic counterpulsation ventricular assist system. This procedure is performed by a physician or other qualified healthcare professional and involves a comprehensive assessment of the device's functionality. The evaluation includes several critical steps: connecting the device to the patient, recording the operational data, and subsequently disconnecting the device. Following these steps, the healthcare professional conducts a thorough analysis and review of the collected data. The findings from this evaluation are then documented in a written report, which serves to inform further treatment decisions and optimize the device's performance. This code is specifically applicable for each patient encounter and is billed on a per-day basis, reflecting the ongoing nature of the evaluation process for patients utilizing this advanced cardiac support technology.

© Copyright 2026 Coding Ahead. All rights reserved.

1. Indications

The procedure associated with CPT® Code 0463T is indicated for patients who have an implantable aortic counterpulsation ventricular assist system. This evaluation is essential for monitoring the device's performance and ensuring optimal functioning. The indications for this procedure may include:

  • Device Functionality Testing Assessment of the operational status of the implantable device to ensure it is functioning correctly.
  • Adjustment of Device Settings Iterative adjustments may be necessary to optimize the device's performance based on the patient's specific needs.
  • Monitoring Patient Condition Regular evaluations are crucial for patients with advanced heart failure or other cardiac conditions requiring mechanical support.

2. Procedure

The procedure for CPT® Code 0463T involves several key steps that ensure a comprehensive evaluation of the implantable aortic counterpulsation ventricular assist system. These steps include:

  • Connection The healthcare professional begins by connecting the implantable device to the necessary monitoring equipment. This step is critical as it establishes the link between the device and the evaluation system, allowing for accurate data collection.
  • Recording Once connected, the device's operational data is recorded. This data may include various parameters related to the device's performance, such as pressure readings and timing of the counterpulsation cycles. Accurate recording is essential for subsequent analysis.
  • Disconnection After the data has been recorded, the healthcare professional carefully disconnects the device from the monitoring equipment. This step must be performed with precision to ensure the safety and comfort of the patient.
  • Analysis and Review Following disconnection, the collected data undergoes a thorough analysis. The healthcare professional reviews the findings to assess the device's performance and identify any necessary adjustments or interventions.
  • Report Generation Finally, a written report is generated that summarizes the evaluation findings. This report is crucial for documenting the procedure and guiding future treatment decisions.

3. Post-Procedure

Post-procedure care following the interrogation device evaluation involves monitoring the patient for any immediate reactions to the evaluation process. The healthcare professional may provide instructions regarding any necessary follow-up appointments or additional evaluations based on the findings from the report. It is also important to ensure that the patient understands the significance of the evaluation results and any adjustments made to the device settings. Continuous monitoring of the patient's condition is essential to ensure the ongoing effectiveness of the implantable aortic counterpulsation ventricular assist system.

Short Descr INTERROG AORTIC VENTR SYS
Medium Descr INTERROG EVAL IMPLT AORTIC VENTR SYS PER DAY
Long Descr Interrogation device evaluation (in person) with analysis, review and report, includes connection, recording and disconnection per patient encounter, implantable aortic counterpulsation ventricular assist system, per day
Status Code Carriers Price the Code
Global Days YYY - Carrier Determines Whether Global Concept Applies
PC/TC Indicator (26, TC) 9 - Not Applicable
Multiple Procedures (51) 9 - Concept does not apply.
Bilateral Surgery (50) 9 - Concept does not apply.
Physician Supervisions 09 - Concept does not apply.
Assistant Surgeon (80, 82) 9 - Concept does not apply.
Co-Surgeons (62) 9 - Concept does not apply.
Team Surgery (66) 9 - Concept does not apply.
Diagnostic Imaging Family 99 - Concept Does Not Apply
APC Status Indicator Procedure or Service, Not Discounted when Multiple
Berenson-Eggers TOS (BETOS) D1E - Other DME
MUE Not applicable/unspecified.
Date
Action
Notes
2021-12-31 Deleted Code deleted
2017-01-01 Added Added
CasePilot

Get instant expert-level medical coding assistance.

Ask about:
CPT Codes Guidelines Modifiers Crosswalks NCCI Edits Compliance Medicare Coverage
Example: "What is CPT code 99213?" or "Guidelines for E/M services"